The operator interface.
Select, install and troubleshoot a touch display at the machine. Read the field notes or compare an industrial monitor for your existing PC.
Read the field notes →Touchscreen selection →
IMD / PRODUCT FILMS
Hardware, in its element.
The operator interface. Installed.
A closer look at the panel, the control cabinet, and the interface your operators use.
Rendered IMD product demonstrations.
Touchscreen selection
Compare touch and brightness options for a display connected to an existing PC.
Q-Series 15.6-inch industrial touch monitor
Hardware for HMI and touch projects
Panel PCs, touchscreen monitors, fanless mini PCs and stainless enclosures, configured to the job at Industrial Monitor Direct.
Latest articles
Troubleshooting
LatestWhy a Copied Project Reports a User Rights Error
The message reports missing user rights, but on a project copied out of its engineering folder the real fault is project state: the copy still carries the identifiers of an integrated project, so the access-protection check fails on open. Verify SIMATIC HMI group membership first; if the account is in the group, stop chasing Windows permissions. Recover the project through the engineering tool, the Project Duplicator or the documented deintegration procedure, never by editing the configuration database.
Selection guide
Which HMI replaces a K-TP 178 micro on an S7-200CN PLC
The S7-200CN stays in service: it runs the same PPI protocol on its RS-485 port as every S7-200, so the discontinued K-TP 178 micro can be replaced by any HMI with a documented S7-200 PPI driver. Select on the driver, the serial port, V/M/I/Q addressing and your screen functions, and match baud rate and station address at both ends before commissioning.
Explainer
Does an HMI memory card hold a restorable panel backup
An HMI memory card restores a replacement panel only when the card is the panel's system memory card and automatic backup was enabled while the old panel ran; a card holding recipes, archives or logs carries no runnable application, and an uploaded backup restores operation without returning an editable project.
Troubleshooting
Why WinCC license keys disappear on an embedded IPC
A WinCC key is a small hidden, location-bound object at the root of the licensed volume, so power loss, write filters, bad sectors, defragmentation, image restores and cleanup tools destroy or hide it with the volume. Rank the causes by what the Automation License Manager reports — missing, defective or expired — and fix the storage cause instead of re-transferring the key.
How-to
SIWAREX HMI example projects for WinCC Professional
Yes: the vendor's SIWAREX FAQ lists an example for PC-based WinCC next to the TP700 Comfort Panel project, and a WP351 example exists for WinCC Unified. Qualify the download against three documented facts — engineering tool and version, runtime target, SIWAREX model — then carry its weighing functions across through one verified path: module to CPU1214, CPU1214 to the 1513, 1513 to HMI external tags, rebound from a mapping list.
Troubleshooting
Why PC Adapter MPI Settings Fail on a PPI S7-200 Port
Set the PG/PC interface to PC Adapter (PPI), USB, and the CPU 222 port's factory rate of 9.6 kbit/s and Micro/WIN finds the station; PC Adapter (MPI) at 19.2 kbit/s over COM1 finds nothing because the profile, rate and port are each wrong for an S7-200. Carry the same PPI settings into the WinCC flexible 2008 connection tab and transfer the project over its own separate channel.
How-to
Keeping WinCC on S7-1500 furnaces when a supplier pushes its own SCADA
Keep WinCC as a written requirement in the purchase specification, with the edition, the license owner and the source-project deliverables named. Give the S7-1500 a symbolic interface over OPC UA so the SCADA stays replaceable without PUT/GET access. Accept a supplier-built platform only when it passes written documentation, reference and license checks.
Explainer
Why WinCC button visibility needs one PLC bit for two conditions
A WinCC Comfort or Basic panel's visibility animation references one controlling tag, so you AND the two conditions in the PLC and bind that single Boolean result to the button. Unified, V7 and Professional editions can also evaluate both tags HMI-side. The overlay-rectangle and multiplex-tag workarounds are not acceptable substitutes for one PLC bit.
How-to
Migrating GP-Pro EX alarms to TIA Portal as alarm words
TIA Portal's word-based discrete alarms reject Boolean trigger tags, so pack the GP-Pro EX alarms into trigger words first: the LGF_MergeBitsToWord block merges 16 Booleans into one Word, and 700 alarms need ceiling(700/16) = 44 words. A V17 library copy upgrades to TIA Portal V18 when its blocks are not write-protected. Map each discrete alarm to its word and bit from a worksheet, and prove one word end to end on the bench before filling the rest.
Explainer
Why WinCC V6 Needs an OPC Server to Reach an S7-200 PPI Port
WinCC V6.0 SP4 carries no channel that can open the S7-200's PPI port directly. The supported route is an OPC server — SIMATIC NET or KEPServerEX — owning the PLC leg, with WinCC reading the server's items as the client.
Explainer
Why a VB ActiveX DLL Does Not Work From WinCC C-Scripts
A Visual Basic ActiveX DLL fails in a WinCC C-script because it is a COM server, not a flat Win32 DLL: the script binds only exported function names, does no COM initialization, and the class must be registered on the runtime PC. Register the DLL with regsvr32 and call it through a small C wrapper that handles the COM lifecycle.
Explainer
Why a TP170B Mono backup cannot move to a newer panel
A TP170B Mono runtime backup restores only to another TP170B Mono and cannot be retargeted to a successor panel. Moving the application to a replacement is an engineering job: open the editable project, the file with the .hmi extension, in WinCC flexible and change the device type to a target that version supports. Establish which file you hold before ordering hardware.