IMDTouch field guide
The operator interface.
Select, install and troubleshoot a touch display at the machine. Read the field notes or compare an industrial monitor for your existing PC.
Read the field notes →Touchscreen selection →
IMD / PRODUCT FILMS
Hardware, in its element.
The operator interface. Installed.
A closer look at the panel, the control cabinet, and the interface your operators use.
Rendered IMD product demonstrations.
Touchscreen selection
Compare touch and brightness options for a display connected to an existing PC.
Q-Series 15.6-inch industrial touch monitor
Hardware for HMI and touch projects
Panel PCs, touchscreen monitors, fanless mini PCs and stainless enclosures, configured to the job at Industrial Monitor Direct.
Latest articles
Troubleshooting
LatestWhy an MT506MV Screen Darkens Seconds After Power-Up
The image-then-fade symptom means the LCD is alive and the illumination chain behind it is failing: lamp, inverter or their connector. Confirm with the flashlight test, hold the panel-terminal voltage steady during the fade, then get the display-assembly part answer from Weintek or its distributor — or replace the unit if the assembly is the only part.
Selection guide
HMI panel as local data logger for a PLCnext controller
An HMI panel with an integrated datalogger, CSV file output and an FTP service can log PLCnext data locally with no separate PC or historian. The decision turns on two numbers: the log volume per day against the panel's free storage, and the controller's protocol server against the panel's driver list, where Modbus TCP is the lowest-friction choice.
Comparison
Why an HMI gain of 0.0166667 rounds your minutes-to-seconds input
Proportion Conversion, not a typed gain, is the right scaling for a Kinco DTools Pro numeric input that takes minutes while the PLC register holds seconds. Set the value range to 0 to 3600 seconds and the proportion range to 0 to 60 minutes and the factor is exact, so a full-scale entry writes the register maximum instead of falling one short. Check the register time base first: a signed 16-bit register caps the preset at 32767 units.
Troubleshooting
Why a Parameter Set Drop-Down Needs a Double Tap on Touch
The Parameter Set Control's Value drop-down opens on touch only when two contacts land as a recognized double-click, and a mistimed pair can block the cell for the mouse until the screen reloads. Pace the second tap about 300 ms after the first on the same spot, keep press-and-hold off, compare kiosk with windowed mode, and only then suspect the tablet's touch driver.
Troubleshooting
Why an unidentified touch panel has missing USB drivers
A working picture proves only the display path. Identify the touch controller from the USB hardware IDs Device Manager shows for each unresolved device, match the vendor with the USB-IF list, then request the panel's touch and panel-function packages separately from the computing unit's platform driver set — one panel can expose two unknown devices and each needs its own driver.
How-to
Updating an MP370 panel image for a WinCC flexible 2007 project
Yes, an MP370 Touch 12-inch with image 6.0.3.2 runs a WinCC flexible 2007 project, but only after a panel image update to 7.2.0.0, the image that release offers for that target. Windows CE staying at 3.00 is normal: the panel image and the CE version are separate identifiers.
Explainer
Login methods on a Unified Comfort Panel by user management
A Unified Comfort Panel in TIA Portal V19 selects its login methods from two conditions: local user management or a central UMC domain, and direct panel operation or a web client. A web client always signs in with username and password only. The panel adds RFID cards, Unified Air biometrics and an alias system function with local users, and RFID cards with a central domain when PM-LOGON Unified is installed.
Explainer
Why runtime passwords do not restrict offline HMI screen edits
No. Runtime user administration authorizes actions inside the running HMI and does nothing to the editable project on the engineering workstation. To restrict offline HMI screen modification you control the project folder, the engineering tool login and the transfer path as three separate boundaries; only a safety program's own protection gives F-PLC-style defense.
Explainer
Why a WinCC Unified Faceplate Interface Has No Static Value Choice
The WinCC Unified faceplate interface offers no static-versus-tag choice: the field takes a tag connection. Pass your constant through a WString or ULInt interface property and apply it in a script on the faceplate's Loaded event, or hold the constants as tags in a PLC data-block array and pass the selected tag.
Troubleshooting
Why a Unified Comfort panel SendEmail needs new runtime values
A dead SendEmail button with no movement on the Processing status tag is usually the panel's retained SMTP record, not SMTP itself. Start a full download, clear the keep-existing SMTP option in the Load preview Runtime values section, and expect roughly five minutes between sends from the same button.
Troubleshooting
Why an Edge app does not autostart on a Unified Comfort Panel
An Industrial Edge app on a Unified Comfort Panel starts on its own only if its containers carry a restart policy such as unless-stopped. Installation alone does not set one, and an HMI Runtime button can open an app's interface or send it a command, but it cannot start a stopped container.
Explainer
Why a WinCC Flexible project on a server needs the tool on your PC
The project files can live on the server, but the engineering tool cannot: WinCC Flexible must be installed on the PC you sit at, and Windows Server 2003 cannot host it. In the reported case, Windows 7 Professional and Windows XP Professional clients running WinCC Flexible SP3 opened the server-hosted projects without the message, while matching users and SIMATIC group memberships changed nothing.