IMDTouch field guide
The operator interface.
Select, install and troubleshoot a touch display at the machine. Read the field notes or compare an industrial monitor for your existing PC.
Read the field notes →Touchscreen selection →
IMD / PRODUCT FILMS
Hardware, in its element.
The operator interface. Installed.
A closer look at the panel, the control cabinet, and the interface your operators use.
Rendered IMD product demonstrations.
Touchscreen selection
Compare touch and brightness options for a display connected to an existing PC.
Q-Series 15.6-inch industrial touch monitor
Latest articles
How-to
LatestConnecting a LOGO! 0BA8 to an MT8050iE HMI over Ethernet
Yes, a LOGO! 0BA8 connects to a Weintek MT8050iE over Ethernet using the Siemens LOGO! (Ethernet) driver in EasyBuilder Pro, with both devices on the same subnet and a server-side Ethernet connection defined in the LOGO! project; prove the link with one read tag, then add writes only after that read follows a value you change in the controller.
Troubleshooting
Why fwDH485 Fails to Start in WinCC Flexible 2008
The messages failed to install fwDH485 and failed to start fwDH485 mean the PC-side DH485 communication component is missing or cannot start; a Device Manager driver update does not prove it. Repair it through the documented WinCC flexible installer, make Use DH485 selectable in the SIMATIC HMI DH485 control panel, and only then test the serial link to the SLC 5/03.
How-to
How to timestamp Weintek HMI alarm history
Timestamp the history with the panel's own real-time clock: save every event in the Event (Alarm) Log, retrieve the records with an Event Display, and set the clock from the panel's date and time setup or the documented settable system registers. The S7-1200 supplies the trigger bits only; its clock is not needed.
How-to
Connect an S7-400H to WinCC Professional with a Device Proxy
Yes: keep the S7-400H project in SIMATIC Manager under STEP 7 V5.6, build the WinCC Professional V15.1 runtime station in TIA Portal, and join the two projects with a Device Proxy. Enable the redundancy option on the SIMATIC S7-300/400 connection so the runtime follows the active H-CPU, then prove the switchover on a bench before the plant relies on it.
Troubleshooting
Why a TP177 project hides the faceplate option in WinCC Flexible
WinCC flexible hides the faceplate command because the configured TP177 target cannot execute faceplates; only Multi Panels and some Mobile Panels can run them. Reinstalling WinCC flexible 2008 SP5 will not bring the option back. Confirm with a test project on a capable target, then either retarget the project or build the interface from ordinary grouped objects.
Explainer
Why AD short-name logon needs the default domain feature
A successful Active Directory import does not enable short-name logon. On WinCC Unified V19 Update 5 with UMC V2.15.3, a Windows-backed account must be entered as DOMAIN\username at both the UMC Web UI and the runtime. The option to omit the domain prefix for the default domain is documented from WinCC Unified V21 Update 1, so the upgrade is the supported path; alias fields and config-file edits are not substitutes.
Explainer
Unified Comfort panel OPC UA client and server roles in V17
From V17, a Unified Comfort Panel offers both an OPC UA server and an OPC UA Data Access client, so it exchanges process data with a third-party controller in either direction. Each connection pairs one server endpoint with one client; two clients cannot talk to each other. Unified PC Runtime adds the connection to OPC UA servers in V17; pick the panel's role from what the controller's specification says it provides.
Explainer
How One HMI Runtime Places Windows on Two Monitors
On an extended desktop, one HMI runtime places each window by its X coordinate: the left display starts at X=0 and the right display starts at X beyond the left display's width. A runtime that exits normally reopens at its saved position, so a boot-time layout comes from startup launch order plus per-monitor window coordinates.
Troubleshooting
Why a TP700 Alarm Timestamp Shows Only Seconds
An alarm screen that shows whole seconds does not prove the stored event time lacks milliseconds, and a display format cannot add precision the record never captured. Check where the timestamp is assigned, compare the alarm view against the archived record, and if the runtime alarm view offers only whole seconds, capture the event time in a PLC-side record.
How-to
Why WinCC Unified screen windows replace template screens
WinCC Unified has no global template screens; you build the layout from a host screen holding screen windows, keep navigation in the host, change only the content window for page changes, and drive menu highlighting from one shared selection state routed through the same path for menu clicks and application-initiated navigation.
How-to
WinCC V13 SP1 PDF viewer object on Runtime Advanced and Comfort Panels
WinCC V13 SP1 adds a standard PDF viewer object for WinCC Runtime Advanced, Comfort Panels and second-generation Mobile Panels, with the HMI at version V13.0.1.0 or higher. Place the object from the toolbox, enter the PDF path and file name, and wire buttons to the PDF* functions such as PDFGotoPage and PDFZoomIn — no script is required.
Troubleshooting
Why an HMI VNC Session Shows a Black Screen but Input Works
When a VNC session to an HMI authenticates, stays black, and clicks at known button positions still actuate the physical panel, the remote-control path is healthy and only the framebuffer-update path is failing. Compare the local screen, confirm authentication, run one observed input test, then take the display-delivery branch: check the access route and client, and get the panel firmware or engineering-software revision that restores screen delivery. Leave tags, drivers and cabling alone.