IMDTouch field guide
The operator interface.
Select, install and troubleshoot a touch display at the machine. Read the field notes or compare an industrial monitor for your existing PC.
Read the field notes →Touchscreen selection →
IMD / PRODUCT FILMS
Hardware, in its element.
The operator interface. Installed.
A closer look at the panel, the control cabinet, and the interface your operators use.
Rendered IMD product demonstrations.
Touchscreen selection
Compare touch and brightness options for a display connected to an existing PC.
Q-Series 15.6-inch industrial touch monitor
Hardware for HMI and touch projects
Panel PCs, touchscreen monitors, fanless mini PCs and stainless enclosures, configured to the job at Industrial Monitor Direct.
Latest articles
Troubleshooting
LatestWhy StartProgram fails to open the keyboard on Unified PC runtime
A StartProgram keyboard launch that fails with CF_R_CANCELLED and a rejected promise is usually the calling script, not Windows: the method runs asynchronously, so declare the calling script async and await the call. Then test a harmless executable such as notepad.exe through the same call before trying keyboard paths, cmd.exe wrappers or permissions.
Troubleshooting
Why a String Change Trigger Misses HMI Logout
A String Change trigger on the HMI user name fires when someone logs in but not when logout clears the name, because the runtime ends the session instead of editing text. Detect logout with an Express Condition comparing $Logout_Time with 0, which covers manual logout and automatic expiry alike, and attach the login macro to the OK key of the User Login (40003) keyboard.
Troubleshooting
Why WinCC Flexible Shows an Empty Screen After Migration
WinCC flexible 2008 shows an empty screen at startup when its stored last-project location is a network station that is offline. Clear the recent-project entry under the WinCC flexible 2008 registry key, point it at a local folder, and migrate only from a local-drive copy. Do the ProTool migration on SP2, because SP3 removed the ProTool import, and keep the license key on either the XP virtual machine or the Windows 7 host, never both.
Explainer
How HMI Audit Trails Record Tag Changes With User and Time
An HMI audit trail writes each operator tag change to a file with the logged-in user and a timestamp; a tag-value archive only shows what the value was. Enable the audit option on Comfort panels and RT Advanced, the Unified audit logging on Unified targets, and prove attribution with two accounts on a bench.
Explainer
Comfort Panel backlight switch-off: why the screen stays lit
A Comfort Panel gives you three separate idle functions: screensaver, backlight dimming and backlight switch-off. Only backlight switch-off removes the light; a screensaver changes the picture and dimming only lowers it, so both leave the panel lit. Set the backlight switch-off timer to the required idle interval and the screen goes dark while the runtime keeps running.
Explainer
Why a Windows 10 panel PC needs a controlled shutdown
A Windows 10 panel PC running SCADA and SQL must receive the operating system's shutdown command before machine power is removed. Cutting the supply interrupts file-system writes, database transactions and pending updates, and a clean reboot does not prove the records survived. Give the machine a SCADA shutdown button or remote task, a UPS with an automatic trigger for supply failures, and an interlock that removes power only after Windows is down.
Troubleshooting
Why WinCC Flexible 2008 Closes a Project After an Interrupted Save
A save killed in Task Manager leaves the project file internally inconsistent, so WinCC Flexible 2008 reports the unloadable data and closes the project when you acknowledge the error. A control project on the same PC and the failed copy on a second PC separate file damage from an installation fault. Recover from the newest pre-hang backup and accept it only after a save-close-open cycle passes.
How-to
Screenless PLC HMI Over VNC: Where the Server Lives
The HMI server lives in the controller, not on your computer. Build the screens in the engineering software, enable the controller's VNC server using the documented VNC Server Management settings, transfer the application, and point a VNC viewer such as TightVNC Viewer or RealVNC at the controller's IP address. A screenless model serves the same screens a panel would; the computer is only display, mouse and keyboard.
Troubleshooting
WinCC Runtime Faceplates: Slow Loading on Screen Activation
Screen activation time equals parse time plus serialized per-instance binding on the UI thread plus the S7 read jobs the screen's tag set needs. Repeat-open speed, core pinning and a bisection of faceplate instances split the delay; inconsistent multi-minute loads point to request packing, optimized DB access, acquisition cycles or stale tag addresses.
Troubleshooting
Why TIA Portal V16 graphics lose their transparent background
TIA Portal V16 delivers its WinCC library graphics with a solid light-gray background instead of usable transparency, so the runtime paints a gray rectangle; the fault is in the pictures, not your installation. Set the object's Transparent color to the picture's background, copy the graphic from a V15.1 reference project, or drag it from an extracted, linked copy of the graphics library; where a Basic Panel snaps the color, use one of the source-based fixes.
Troubleshooting
Why Comfort Panel simulation fails with the pdata.fwc error
When Start Simulation on a Comfort Panel ends with the pdata.fwc configuration file could not be loaded and HmiRTm.exe stops, a TIA Portal V17 installed beside an older version has broken the shared simulation component: repair V17 from its DVD or ISO without uninstalling first, then apply all pending V17 updates. If only one project fails, delete the Diagnostic Viewer control from the screens and rebuild all software; as a last resort, recreate the HMI device.
Troubleshooting
Why a Unified panel trend plots only the current value
The Trend control anchors its time axis at UTC 0, so on a panel running at any other offset the plotted window sits hours away from the samples being written and only the newest value lands inside it. Set the Trend control's own Time zone property to the panel's offset; a firmware update does not fix it.