IMDTouch field guide
The operator interface.
Select, install and troubleshoot a touch display at the machine. Read the field notes or compare an industrial monitor for your existing PC.
Read the field notes →Touchscreen selection →
IMD / PRODUCT FILMS
Hardware, in its element.
The operator interface. Installed.
A closer look at the panel, the control cabinet, and the interface your operators use.
Rendered IMD product demonstrations.

Touchscreen selection
Compare touch and brightness options for a display connected to an existing PC.
Q-Series 15.6-inch industrial touch monitor
Hardware for HMI and touch projects
Panel PCs, touchscreen monitors, fanless mini PCs and stainless enclosures, configured to the job at Industrial Monitor Direct.
Latest articles
Troubleshooting
LatestModbus Server Port 8000 Causes HMI Client Read Timeouts
When an external Modbus TCP master connects to an HMI's Local Modbus Server but every read times out, the server is on its nonstandard default port. Change the Local Modbus Server port from 8000 to 502 in System Parameters, Model tab on the iE series, point the master at 502, and verify that every mapped address answers. A local bit with no mapping row stays unreadable regardless of port.

Troubleshooting
Why WinCC Unified Autologin Works Only on the Runtime Server
The automatic login you enable in SIMATIC Runtime Manager authenticates only a browser session opened on the WinCC Unified Runtime server itself. A browser on another computer is an external web client and always requires its own login, even when the server-side autologin user and password are configured correctly.

Troubleshooting
Why Copy RAM to ROM fails when SCOUT downloads an HMI station
SCOUT's Copy RAM to ROM batch fails with 'copy RAM to ROM not performed for any device' because the batch includes an integrated WinCC flexible RT station that SCOUT cannot load; one failed HMI transfer aborts the ROM write for every device. Deselect the HMI station in SCOUT's target device selection, download and copy the SIMOTION CPU alone, and load the runtime with WinCC flexible ES through its own Transfer settings.

Troubleshooting
Why a WinCC named connection fails when TCP/IP tags work
When 3 of 5 named S7 connections work and TCP/IP tags succeed on the 2 that fail, the server, the channel and the network are already proven and the fault sits in configuration identity. Compare the NetPro partner bindings, the server's PC station and each tag's connection assignment against a working connection instead of rebuilding anything.

Explainer
Why WinCC Professional full screen hides a second HMI runtime
WinCC Professional Runtime in full-screen mode claims the entire work area of the extended desktop by design, so a co-resident Advanced Runtime is hidden behind it, not stopped. Run both runtimes in window mode with one window per monitor, because Advanced Runtime is not released for multi-monitor use and only one Professional Runtime runs in parallel on one operating system.

Troubleshooting
Why SIMOTION technology alarms stay missing on a TIA HMI
Technology alarms are raised in the SIMOTION controller, never configured in the HMI, and reach the panel over an HMI connection once the SIMOTION TO alarms option is enabled in the runtime message settings. Basic Panels do not expose that option; Comfort Panels do. When events arrive without text, updating SCOUT TIA to SP1 HF5 or later and downloading again is the fix.

How-to
Where to Find the Symbol Library in WinCC Graphics Designer
In classic WinCC, the symbol library lives inside the Graphics Designer picture editor: open a PDL picture and select View > Library to expose the Global Library and the project library. You extend it with your own WMF or EMF vector files, and custom ActiveX controls reach the palette through Add/Remove Controls.

Troubleshooting
Why WinCC opens too many TCP connections to a Modbus gateway
A reported behavior of the WinCC Modbus TCP channel opens a separate TCP session for every distinct unit ID, even when all of them sit behind one gateway IP address. The ADAM-4572 documentation gives 8 simultaneous clients, so a design that works on paper can exhaust the gateway. Measure the sessions the installed driver actually opens and keep them within the gateway's limit.

Explainer
When an HMI simulator can talk to a PLC simulator
Yes, when both simulators expose an external communication endpoint of their own; a simulation that only runs logic and motion inside the engineering software offers nothing for the other side to connect to. Point the simulated panel's driver at the simulated controller, prove the path with a two-direction tag test, and fall back to a live controller when either endpoint is missing.

How-to
One reusable HMI object with different variables
EcoStruxure Operator Terminal Expert supports reusable animated objects through the parameter mechanism: the graphic's animations read interface parameters, and each placed instance supplies its own variables. Build the definition first, assign per instance, then prove independence with two test variables held in opposite states; copying a graphic without an interface keeps the original bindings and makes both copies move together.

Explainer
Comfort Panel in STEP 7 V5.x: why a device proxy, not a GSDML
Siemens publishes no standalone GSDML for the 0AX1 Comfort Panel refresh, so you cannot insert it into STEP 7 V5.x HW Config as a generic PROFINET device. The documented path is a Device Proxy exported from the WinCC (TIA Portal) project, with the panel present in the TIA catalog through a version-matched HSP such as V14 HSP 0211. Per-panel fault diagnosis over PROFINET then comes from the PNIODiag block in the STEP 7 CPU.

Explainer
What activation FactoryTalk View Studio 4.00 supports
FactoryTalk View Studio 4.00 runs on both classic EVRSI activation and FactoryTalk Activation, so either license type is valid for it. The RSView-to-FactoryTalk rename happened at version 5.00, not 4.00. What the version number never tells you is which activation a specific offer bundles, so make the seller state the activation and the version in writing before you buy.