In the ever-evolving landscape of industrial computing, safety standards are crucial for ensuring that technological advancements do not come at the expense of operational security. One of the most significant benchmarks for achieving safety compliance in this domain is the IEC 62368-1 standard. This global regulation has redefined the way manufacturers and designers approach the production of audio, video, and information technology equipment, which are extensively used in industrial settings. As industries increasingly depend on advanced, integrated technologies, the implementation of such safety standards becomes paramount to ensure the integrity and safety of devices deployed in diverse environments.

This article delves into the significance of IEC 62368-1, how it is shaping the safety of industrial computers, and the essential requirements that manufacturers need to meet to stay compliant.

What is IEC 62368-1?

IEC 62368-1 is an international safety standard developed by the International Electrotechnical Commission (IEC). Officially titled "Audio/video, information, and communication technology equipment – Part 1: Safety requirements", this standard applies to a wide array of modern devices used in both commercial and industrial environments.

Historically, safety standards in the field of electronics and information technology were governed by two separate standards: IEC 60065 for audio/video equipment and IEC 60950-1 for information technology equipment. However, with the convergence of these technologies, the need for a unified safety standard arose, leading to the development of IEC 62368-1. This standard merges the safety requirements for both types of equipment, providing a single, cohesive approach.

The third edition of IEC 62368-1, the most recent revision, continues to adopt the hazard-based safety engineering (HBSE) methodology, which focuses on identifying potential hazards associated with specific devices and implementing design features that reduce the likelihood of those hazards causing harm. The approach considers various safety risks, such as:

  • Electrical shock: Ensuring proper insulation and grounding.
  • Fire hazards: Using fire-resistant materials and protective enclosures.
  • Mechanical risks: Mitigating potential injury from moving parts or sharp edges.
  • Energy sources: Managing thermal and electrical energy to avoid dangerous levels of heat or electric shock.

Compliance with this standard is a critical requirement for manufacturers to ensure that their products are globally recognized as safe and fit for use in demanding environments.

The Significance of UL 62368-1 in North America

While IEC 62368-1 is the global standard, manufacturers targeting the North American market also need to consider the UL 62368-1 certification, which aligns closely with the IEC version but is tailored to the region’s specific regulatory framework.

Underwriters Laboratories (UL) is one of the primary certification bodies responsible for evaluating and testing compliance with IEC 62368-1 within North America. The UL 62368-1 certification process ensures that products meet the stringent safety requirements established by both the IEC and local safety authorities. Manufacturers aiming to distribute their equipment in North America often seek UL certification to gain access to a broader market and reassure customers that their products comply with rigorous safety standards.

Although UL 62368-1 certification closely mirrors the international standard, it also includes certain additional criteria and testing methods that reflect North American safety protocols. These may include specific evaluations for:

  • Electrical infrastructure compatibility: Ensuring devices function safely with regional voltage and power grid standards.
  • Environmental factors: Considering the climatic and operational conditions that may differ between global regions.

Achieving UL certification not only helps in regulatory compliance but also provides a competitive edge in terms of market acceptance and trust among consumers.

Key Differences Between IEC 62368-1 and UL 62368-1

Though the IEC 62368-1 and UL 62368-1 share the same core principles, they differ in terms of certification processes, regional focus, and specific technical requirements. Below are some key differences:

  1. Certification Authority: IEC 62368-1 is an internationally recognized standard, while UL 62368-1 pertains to the certification process managed by UL, focusing primarily on the North American market.
  2. Regional Applicability: IEC 62368-1 is accepted across many countries and regions globally, whereas UL 62368-1 is particularly relevant for manufacturers aiming to distribute their products in the U.S. and Canada.
  3. Evaluation Criteria: UL certification may involve additional testing criteria or regional-specific safety features, ensuring compliance with North American electrical and environmental safety standards.

The Role of IEC 62368-1 in the Global Transition to Safer Technology

The global transition to the third edition of IEC 62368-1 marks a significant shift toward a more unified approach to safety. As industries increasingly adopt interconnected technologies like IoT (Internet of Things) and edge computing, this standard plays a vital role in ensuring the safe operation of equipment in harsh environments.

For example, industrial computers often operate 24/7 in remote and challenging locations, making operational reliability essential. Meeting IEC 62368-1 standards ensures that these devices can withstand a variety of potential hazards without compromising performance or safety.

Importance of UL-Listed Industrial Computers in Harsh Environments

Industrial computers certified under UL 62368-1 are designed to thrive in environments where standard commercial devices might fail. These computers, built for edge computing and mission-critical tasks, are often deployed in situations where downtime is not an option, and maintenance is infrequent.

In such environments, UL certification provides an additional layer of assurance that the equipment will perform reliably even in extreme conditions. UL-listed industrial computers are rigorously tested for:

  • Temperature tolerance: Ensuring stable performance in high heat or cold.
  • Shock and vibration resistance: Protecting internal components from damage due to physical impacts.
  • Electrical integrity: Preventing short circuits and other electrical failures that could lead to fires or hazardous malfunctions.

Conclusion

Adhering to safety standards such as IEC 62368-1 and UL 62368-1 is more than just a regulatory requirement—it's a commitment to the longevity, reliability, and safety of industrial computing devices in mission-critical deployments. As the technological landscape continues to evolve, with increasing demand for interconnected and automated systems, ensuring compliance with these standards will not only enhance device safety but also protect operators and infrastructure from potential hazards.

For companies seeking advanced industrial computers that comply with the latest safety standards, it’s important to engage with reliable suppliers. These computers are designed for the most challenging environments, offering the durability and performance necessary for 24/7 operations. If you’re interested in learning more about high-performance, UL-listed industrial computers that meet the requirements of IEC 62368-1, contact the experts at IMDTouch or email us at support@IMDTouch.com for detailed product information and consultation.