Skip to product information
NaN of -Infinity

10.4" all-in-one Panel PC, 1024x768, Intel Celeron J4125

10.4" all-in-one Panel PC, 1024x768, Intel Celeron J4125

BASIC CONFIGURATION (REQUIRED)


TouchscreenCapacitive
Screen BrightnessStandard
Operating SystemNone

OTHER CONFIGURATIONS (OPTIONAL)


Power InputDirect DC(12VDC-36VDC)
Mounting
Mounting Instruction Video
Panel Mount
Upload Customer Specification Documentations

DISPLAY CONFIGURATIONS (OPTIONAL)


Display Bonding
Learn More
None
Auto Brightness SensorNone
Screen Film AddonNone

PC CONFIGURATIONS (OPTIONAL)


CPUDefault(See Specification)
MemoryDefault(See Specification)
Storage(SSD)Default(See Specification)
WiFi + BluetoothNone
Cellular ConnectivityNone
TouchScreen BehaviorStandard
Auto Power OnEnabled
Requested Delivery Date

Low stock: 2 left

SKU:IMD104-W210-J4125-SD-NONE

$935.25 USD
$935.25 USD
STOCK Sold out
Shipping Calculated At Checkout

Please login to view the download links for the 3D Models.

View full details

IMD104-W200-J4: 10.4" Rugged Industrial Panel PC with Intel® Celeron® J4125

IP65 Fanless Embedded Computer for HMI, SCADA, and 24/7 Harsh Environment Operation

Overview

The IMD104-W200-J4 is a high-performance, all-in-one industrial panel PC engineered for relentless operation in the most demanding industrial settings. Combining a robust, fanless design with comprehensive environmental sealing, this embedded industrial computer delivers uncompromising reliability for critical automation, visualization, and control tasks.

At its core, the Intel® Celeron® J4125 quad-core processor provides ample power for complex HMI/SCADA applications, including native support for Ignition SCADA and Inductive Automation platforms. Its 10.4" XGA display, available with robust touchscreen options, ensures clear visibility and interaction on the factory floor. Built for 24/7 duty, this rugged touchscreen PC is the definitive solution for system integrators and OEMs requiring a durable, long-life computing interface.

Key Features & Benefits

Robust Fanless Architecture

The completely sealed, fanless panel PC design eliminates moving parts, the leading cause of system failure in dusty industrial environments. This ensures silent operation, higher reliability, and immunity to particulate contamination.

IP65 Front Panel Protection

As an IP65 industrial computer, the front panel is completely protected against dust ingress and low-pressure water jets from any direction. It can be cleaned with chemicals and withstands accidental spills, making it ideal for food & beverage, pharmaceutical, and wash-down applications.

Wide-Range Power Input

With a DC 12V to 36V input range, the panel PC is resilient to voltage fluctuations, sags, and surges common in industrial power systems. This feature is critical for automotive, logistics, and mobile applications where stable power is not guaranteed.

Optimized for Industrial Software

Pre-validated for compatibility with leading HMI and SCADA software, this panel PC is an excellent platform for Inductive Automation HMI projects. Its x86 architecture and support for Windows/Linux provide a flexible foundation for running Ignition SCADA edge applications, OPC UA clients, and custom visualization software.

Rugged Connectivity

A comprehensive set of I/O ports, including dual LAN for network segmentation, multiple USB for peripherals, and legacy VGA support, allows for seamless integration into both modern and legacy automation systems.

Extended Temperature Operation

Engineered to perform reliably in an ambient temperature range of -10°C to 60°C, this computer is suited for unregulated environments like warehouses, manufacturing plants, and outdoor enclosures.

Technical Specifications

Category Specification
Display
LCD Size & Resolution 10.4" TFT LCD, 1024 x 768 (XGA)
Brightness 400 cd/m²
Contrast Ratio 1000:1
Touch Screen Options Projected Capacitive, 5-Wire Resistive, or Non-Touch
Computer Core
Processor Intel® Celeron® J4125 Quad-Core (2.0 GHz, burst up to 2.7 GHz)
Memory 4GB DDR4 (User-upgradable to 8GB)
Storage 64GB M.2 SATA SSD (Options: 128GB, 256GB, 512GB)
Connectivity & I/O
USB Ports 2x USB 3.0, 2x USB 2.0
Video Output 1x HDMI, 1x VGA
Network 2x Gigabit LAN (RJ45)
Serial COM 2x RS-232/422/485 (Software-Selectable)
Audio Line-out, Microphone-in
Physical & Power
Power Input DC 12V - 36V (Wide Range, Anti-surge)
Dimensions (W x H x D) 288mm x 231mm x 56.5mm
Weight Approx. 2.5 kg
Mounting Panel Mount (Standard), VESA Mount (Optional)

Environmental Ratings & Durability

This rugged touchscreen PC is built to thrive where standard commercial computers fail.

  • IP65 Rating (Front Bezel): Complete dust protection and resistance to low-pressure water jets, enabling operation in wet, humid, and dusty conditions. Perfect for wash-down areas in food processing or high-particulate environments like woodworking or metal fabrication.
  • Fanless & Solid-State Design: No vents, fans, or spinning hard drives. The system uses passive cooling and an M.2 SSD, making it immune to vibration and shock that would damage conventional computers.
  • Extended Temperature Range: Operates from -10°C to 60°C, ensuring boot-up and stable performance in both freezing cold warehouses and hot industrial facilities without climate control.
  • Robust Metal Chassis: The aluminum alloy enclosure provides excellent EMI shielding and mechanical strength, protecting the internal components from physical impact and electromagnetic interference.

Software & Compatibility

This industrial HMI panel is a versatile platform for a wide range of industrial software, providing a stable and responsive foundation for your most critical applications.

  • Operating Systems: Fully compatible with Windows 10/11 IoT Enterprise, Ubuntu Linux, and CentOS. Drivers are readily available for all major OS versions.
  • Ignition SCADA & Inductive Automation: Certified and recommended as a hardware platform for Ignition SCADA systems. The Intel J4125 processor provides more than enough power for the Ignition Edge platform, running Perspective sessions, OPC UA, and MQTT transmission modules seamlessly.
  • HMI/SCADA Platforms: Ideal for Wonderware System Platform, GE iFIX, Siemens WinCC, AVEVA Edge, and VTScada.
  • OEM & Custom Applications: A perfect fit for OEM machinery, this embedded industrial computer can be delivered as a barebone system for pre-loading with custom software, creating a tailored HMI solution for specialized equipment.

Industrial Applications

Factory Automation & MES: Serves as a robust operator station for PLC control, machine visualization, and Manufacturing Execution System (MES) data entry.
SCADA Visualization: Acts as a remote telemetry unit (RTU) interface or local operator panel for water/wastewater, oil & gas, and energy management SCADA systems.
Process Control: Ideal for chemical, pharmaceutical, and food & beverage industries where IP65 rating is mandatory for hygiene and safety.
Logistics & Warehousing: Withstands the vibrations and temperature swings of material handling equipment, forklift terminals, and automated storage/retrieval systems.
OEM Machinery Integration: Embedded into custom industrial machines, packaging equipment, and test stands as a dedicated, reliable control interface.

Certifications & Compliance

This product meets or exceeds the following international standards, ensuring safety, quality, and global market acceptance.

ISO Certified Manufactured under a certified Quality Management System, ensuring consistent product quality and reliability.
FCC Compliant Limits electromagnetic interference, preventing disruption to other electronic equipment in the United States.
CE Marked Confirms compliance with EU health, safety, and environmental protection legislation, required for sale in the European Economic Area.
RoHS Compliant Restricts the use of hazardous substances (e.g., lead, mercury), making the product safer for the environment and end-of-life disposal.
UL Listed Certified by Underwriters Laboratories for product safety standards, a critical requirement for many North American industrial facilities and insurers.
cUL Certified Canadian equivalent of UL Listing, ensuring compliance with Canadian Safety Standards.
IEC 60068 Verified to withstand environmental stresses such as temperature, humidity, and vibration as per international standards.