Skip to product information
NaN of -Infinity

21.5" all-in-one Panel PC, 1920x1080, Intel Celeron J1900

21.5" all-in-one Panel PC, 1920x1080, Intel Celeron J1900

BASIC CONFIGURATION (REQUIRED)


TouchscreenCapacitive
Screen BrightnessStandard
Operating SystemNone

OTHER CONFIGURATIONS (OPTIONAL)


Power InputDirect DC(12VDC-36VDC)
Mounting
Mounting Instruction Video
Panel Mount
Upload Customer Specification Documentations

DISPLAY CONFIGURATIONS (OPTIONAL)


Display Bonding
Learn More
None
Auto Brightness SensorNone
Screen Film AddonNone

PC CONFIGURATIONS (OPTIONAL)


CPUDefault(See Specification)
MemoryDefault(See Specification)
Storage(SSD)Default(See Specification)
WiFi + BluetoothNone
Cellular ConnectivityNone
TouchScreen BehaviorStandard
Auto Power OnEnabled
Requested Delivery Date

Low stock: 2 left

SKU:IMD215-W210-J1900-SD-NONE

$1,070.55 USD
$1,070.55 USD
STOCK Sold out
Shipping Calculated At Checkout

Please login to view the download links for the 3D Models.

View full details

21.5" Fanless Industrial Panel PC | IP65 Rugged Touchscreen Computer

Intel Celeron J1900 Quad-Core | 24/7 Harsh Environment Operation | Ignition SCADA & HMI Ready

Overview: Engineered for Industrial Resilience

Our 21.5" all-in-one industrial panel PC represents the pinnacle of rugged computing technology, specifically engineered to deliver uncompromising performance in the most demanding industrial environments. Powered by the reliable Intel Celeron J1900 quad-core processor, this fanless panel PC eliminates mechanical failure points while providing substantial processing power for complex HMI visualization, SCADA systems, and industrial automation applications.

The unit's IP65-rated front panel provides complete protection against dust ingress and low-pressure water jets, making it ideal for washdown areas, food processing plants, and manufacturing environments where exposure to contaminants is constant. With an operating temperature range of -10°C to 60°C, vibration resistance, and 24/7 operation capability, this embedded industrial computer ensures continuous operation where conventional computers would fail.

Designed for seamless integration with industry-leading software platforms including Ignition SCADA and Inductive Automation HMI applications, this panel PC serves as the perfect visualization and control interface for modern industrial operations, OEM machinery, and factory automation systems.

Key Features & Industrial Advantages

Rugged Construction

  • IP65 Front Seal: Complete protection against dust and water for harsh environments
  • Fanless Thermal Design: No moving parts eliminates fan failure and reduces maintenance
  • Aluminum Alloy Chassis: Durable, corrosion-resistant construction with excellent heat dissipation
  • Vibration & Shock Resistant: Withstands 5G vibration and 50G shock per IEC 60068 standards

Premium Display Technology

  • 21.5" Full HD IPS Display: 1920x1080 resolution with wide viewing angles
  • High Brightness & Contrast: 300 cd/m² brightness and 1000:1 contrast ratio for clear visibility
  • Projected Capacitive Touch: 10-point multi-touch with excellent responsiveness
  • Optical Bonding Option: Reduced glare and enhanced readability in high-ambient light

Industrial Connectivity

  • Wide Voltage Input: 12V-36V DC power supply for vehicle and industrial power systems
  • Legacy & Modern I/O: Comprehensive ports including RS232 serial for industrial devices
  • Dual Display Support: HDMI and VGA outputs for simultaneous monitoring
  • Expansion Capabilities: Mini-PCIe and SIM slots for cellular and wireless connectivity

Technical Specifications

Component Specification Industrial Benefit
Display 21.5" TFT LCD, 1920×1080, 300 cd/m², 1000:1 contrast Crisp visualization for complex HMI and SCADA interfaces
Processor Intel Celeron J1900 Quad-Core, 2.0GHz (2.4GHz burst) Adequate power for industrial applications with low power consumption
Memory 4GB DDR3L (upgradable to 8GB) Smooth performance for multi-tasking industrial applications
Storage 64GB mSATA SSD (upgradable to 512GB) Shock-resistant storage for vibration-intensive environments
Touch Interface 10-point projective capacitive or 5-wire resistive Flexible options for gloved or bare-finger operation
I/O Ports 2×USB 3.0, 2×USB 2.0, 2×RS232, HDMI, VGA, Gigabit LAN, Audio Connectivity for industrial peripherals, PLCs, and legacy equipment
Power Input DC 12V~36V (wide voltage with reverse polarity protection) Compatible with industrial power systems and vehicle applications
Dimensions 557mm (W) × 345mm (H) × 63mm (D) Slim profile for space-constrained industrial panels and enclosures

Environmental Ratings & Durability

IP65 Protection

Complete dust ingress protection and resistance to low-pressure water jets from any direction. Ideal for washdown areas and dusty manufacturing environments.

Operating Temperature

-10°C to 60°C (14°F to 140°F) range ensures reliable performance in both refrigerated and high-temperature industrial settings.

Vibration & Shock

Withstands 5G vibration and 50G shock per IEC 60068 standards, ensuring reliability in transportation and heavy machinery applications.

24/7 Operation

Designed for continuous operation in mission-critical applications with no performance degradation over extended periods.

Software & Industrial Platform Compatibility

This industrial HMI panel is engineered for seamless integration with industry-standard software platforms and operating systems, providing a robust foundation for your industrial automation projects.

Ignition SCADA & Inductive Automation

Specifically tested and validated for optimal performance with Ignition SCADA from Inductive Automation. The Intel Celeron J1900 processor provides sufficient processing power for Ignition's gateway and client components, while the high-resolution display offers exceptional visualization for Ignition Perspective and Vision modules. This makes it an ideal Ignition SCADA PC for modern industrial operations.

Operating Systems

Windows 10/11 IoT
Linux Distributions
Ubuntu
Debian

SCADA/HMI Platforms

Ignition by Inductive Automation
Wonderware System Platform
Siemens WinCC
GE iFIX
AVEVA Plant SCADA

Industrial Protocols

OPC UA
Modbus TCP/RTU
EtherNet/IP
PROFINET
MQTT

Industrial Applications

Factory Automation & Manufacturing

  • Machine HMI interfaces for CNC, injection molding, and assembly equipment
  • Production line monitoring and control systems
  • Quality inspection stations with vision system integration
  • Andon systems for real-time production status

Process Industries & Utilities

  • SCADA visualization for water/wastewater treatment facilities
  • Oil & gas monitoring and control panels
  • Power distribution and energy management systems
  • Chemical processing plant operator interfaces

Logistics & Transportation

  • Warehouse management and inventory control systems
  • Automated guided vehicle (AGV) control interfaces
  • Fleet management and telematics displays
  • Port and terminal operation monitoring

Food & Pharmaceutical

  • Washdown-area compliant processing line controls
  • Batch processing and recipe management stations
  • Clean room monitoring and compliance tracking
  • Packaging line operation and quality assurance

Certifications & Compliance

This industrial panel PC meets or exceeds global standards for safety, electromagnetic compatibility, and environmental performance, ensuring compliance with industrial regulations worldwide.

Certification Status Significance for Industrial Applications
ISO Certified Certified Manufactured under quality management system ensuring consistent product quality and reliability
FCC Compliant Compliant Meets US electromagnetic interference standards, preventing disruption to sensitive industrial equipment
CE Marked Marked Complies with European health, safety, and environmental protection standards for EU market access
RoHS Compliant Compliant Restricts use of hazardous substances, ensuring environmental responsibility and worker safety
UL Listed Listed Verified electrical safety by Underwriters Laboratories for North American industrial applications
cUL Certified Certified Meets Canadian safety standards, equivalent to UL listing for Canadian market compliance
IEC 60068 Compliant International standard for environmental testing confirming durability under harsh conditions
SPECIFICATION
Loading... Specification
DIMENSION / CUT-OUT
Loading... Dimension/Cut-Out